Air Circuit Breaker ACB
3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker
  • 3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker

3200 Amp Acb Air Blast Ckt Breaker

Wenzhou XiFa Electric Power Equipment Co., Ltd minangka pabrik profesional kanggo ngasilake pemutus sirkuit udara lan pemutus sirkuit kasus cetakan, kayata 3200 amp acb air blast ckt breaker. iku cocok kanggo tanduran industri tugas abot lan bangunan komersial ukuran gedhe. Kanggo mesthekake respon fault cepet, Wenzhou XiFa Electric Power Equipment Co., Ltd adopts tembaga konduktivitas dhuwur karo plating salaka ing lumahing minangka kontak. Unit trip lan mekanisme operasi bakal dites sadurunge lan sawise saben 3200 amp acb air blast ckt breaker rampung.

3200 amp acb air blast ckt breaker minangka piranti protèktif inti ing sistem distribusi voltase kurang, sing nduduhake aplikasi sing wiyar ing sektor industri, komersial, lan infrastruktur. Keuntungan saka paramèter kinerja sing apik lan desain modular saka 3200 amp acb air blast ckt breaker.

3200 Amp Acb Air Blast Ckt Breaker3200 Amp Acb Air Blast Ckt Breaker

Fitur kasebut bisa ditampilake ing ngisor iki:

1. Kinerja Listrik

Acb air blast ckt breaker nduweni arus dirating 3200A lan cocok kanggo jaringan telung fase AC 50 Hz kanthi tegangan operasi sing dirating nganti 690V. Kapasitas breaking sawijining kisaran saka 65 kA kanggo 100 kA, kang pemutus sirkuit online bisa èfèktif nangani arus fault short. Dilengkapi karo unit trip cerdas, nyedhiyakake proteksi patang tahap kalebu wektu tundha suwe, wektu tundha cendhak, cepet, lan fault lemah opsional, kanthi akurasi ambang proteksi ± 5%.

2. Sistem Monitoring Cerdas

Saben 3200 amp acb air blast ckt breaker bisa ngatur modul komunikasi cerdas sing ndhukung protokol Modbus-RTU utawa Profibus-DP. Bisa ndhukung ngawasi wektu nyata luwih saka 20 paramèter kayata saiki, voltase, lan faktor daya. Bentuk gelombang kesalahan lan data operasional bisa dianalisis liwat panel tampilan LED utawa liwat piranti lunak manajemen berbasis PC.

3200 Amp Acb Air Blast Ckt Breaker

Parameter produksi:

Rated Frame Saiki

A

3200

Rated Saiki

A

2000/2500/2900/3150

Ultimate Breaking Kapasitas

kA

100

Service Breaking Kapasitas

kA

80

Urip Listrik

kaping

6000

urip mekanik

kaping

10000 kanggo pangopènan free 20000 kanggo pangopènan

Tegangan Rated

V

400 kanggo 690

Rated Insulation Voltage

V

1000

Impulse Tahan Tegangan

kV

12

3200 Amp Acb Air Blast Ckt Breaker

FAQ produk:

P: Sepira cepet 3200 amp acb air blast ckt breaker nanggapi kesalahan?

A: 3200 amp acb air blast ckt breaker bisa ngganggu arus fault ing milliseconds, kanggo nyilikake karusakan peralatan lan nyuda downtime ing sistem kritis.

P: Sepira kerepe 3200 amp acb air blast ckt breaker kudu perawatan?

A: jadwal pangopènan preventif saka 3200 amp acb air blast ckt breaker bisa dituduhake minangka ing ngisor iki:

1. Tes Operasi Mekanik: Tindakake saben 500 operasi utawa saben 12 sasi, endi wae sing luwih dhisik.

2. Test Resistance Kontak: Nindakake saben 3 taun utawa sawise gangguan short-circuit.

3. Insulation Test: Ing lingkungan karo asor relatif ndhuwur 85%, nindakake saben 6 sasi.

P: Apa kahanan instalasi sing kudu dianggep?

A: kahanan instalasi saka 3200 amp acb air blast ckt breakers dituduhake ing ngisor iki:

1. Suhu udara sekitar ora kudu luwih dhuwur tinimbang +40 ℃ lan ora luwih murah tinimbang -5 ℃. Suhu rata-rata saben dina ora bisa ngluwihi +35 ℃.

2. Panggonan instalasi kudu ing dhuwur 2000 meter utawa ngisor. Yen ora, kapasitas break bisa mudhun 1% kanggo saben 100 meter munggah.

3. Kahanan atmosfer ana ing suhu sekitar +40 ℃. Kelembapan relatif ora ngluwihi 50%. Kangge, ing suhu sing luwih murah, tingkat kelembapan sing luwih dhuwur diidini. Sajrone sasi paling lembab, rata-rata suhu minimal saben wulan ora ngluwihi +25 ℃, lan rata-rata saben wulan asor relatif maksimum ora ngluwihi 90%, nalika ngidini kanggo kondensasi ing lumahing produk amarga fluktuasi suhu.

WorkshopWorkshopWorkshopWorkshopWorkshopWorkshopWorkshopWorkshopWorkshop




Hot Tags: 3200 Amp ACB Air Blast Circuit Breaker, High Voltage Air Blast Circuit Breaker, Air Blast ACB Grosir
Kirim Pitakonan
Info kontak

Kanggo njaluk kutipan ASAP

XiFa-panyedhiya peralatan listrik dipercaya
X
Kita nggunakake cookie kanggo menehi pengalaman browsing sing luwih apik, nganalisa lalu lintas situs lan nggawe konten pribadi. Kanthi nggunakake situs iki, sampeyan setuju kanggo nggunakake cookie. Kebijakan Privasi
nolak Nampa